Specifications
- Evaluation inputs
- One- and two-channel
- Model
- Basic device
- Number of outputs, safety related, delayed, semiconductors
- 0.000
- Number of outputs, safety related, delayed, with contact
- 3.000
- Number of outputs, safety related, undelayed, semiconductors
- 0.000
- Number of outputs, safety related, undelayed, with contact
- 2.000
- Number of outputs, signalling function, delayed, semiconductors
- 0.000
- Number of outputs, signalling function, delayed, with contact
- 0.000
- Number of outputs, signalling function, undelayed, semiconductors
- 0.000
- Number of outputs, signalling function, undelayed, with contact
- 0.000
- Performance level according to EN ISO 13849-1
- Level e
- Rail mounting possible
- Y
- Rated control supply voltage Us at AC 50HZ (V)
- 24
- Rated control supply voltage Us at AC 60HZ (V)
- 24
- Rated control supply voltage Us at DC (V)
- 24
- SIL according to IEC 61508
- 3
- Stop category according to IEC 60204
- 0 + 1
- Suitable for monitoring of emergency-stop circuits
- Y
- Suitable for monitoring of magnetic switches
- Y
- Suitable for monitoring of optoelectronic protection equipment
- Y
- Suitable for monitoring of position switches
- Y
- Suitable for monitoring of proximity switches
- Y
- Suitable for monitoring of tactile sensors
- Y
- Suitable for monitoring of valves
- Y
- Type of electric connection
- Spring clamp connection
- Type of safety according to IEC 61496-1
- 4
- Voltage type for actuating
- AC/DC
- With approval according to UL
- Y
- With approval for BG BIA
- Y
- With approval for T?V
- Y
- With detachable clamps
- Y
- With feedback circuit
- Y
- With start input
- Y